More and more enterprises are using belt filter press, and Tiantai Fengton Filter Material Co.,Ltd is specialized in producing belt filter cloth, vertical filter press filter, plate and frame filter cloth filter manufacturers , In the actual use of filter cloth, the customer often reflect the belt filter press filter cloth mud mud phenomenon, the beginning is that the quality of filter cloth, and later through the meticulous and often, and constantly summed up, we summed up a few Run the reasons for the mud, the main cause of death due to individual companies did not seriously look at the instructions, the belt filter press and not enough understanding,
Reason one: the filter itself is generally caused by the structural problems
1 .. in the mud at the mouth plus a baffle limit, leaving thirty centimeters on each side
2. Check the downside control device and the filter belt tensioner is not a problem
4. With the tape with too fast, gravity dehydration is not sufficient
5 into the mud flow is too large, part of the sludge dewatering machine is squeezed out
6 filter cloth is not clean, flushing water pressure is not enough, or nozzle clogging
3. Under the re-test, look at the dosage is not appropriate
Reason two: dispensing concentration is not too small? Increase the concentration to do a small test to see. Flocculant selection problems, the effect is not good, can not form a large and stable alum, you rinse the filter with the water blockage or water pressure is too small to run mud, your sludge and dosage is not adjusted
Reason three: is the sludge deterioration or sludge sedimentation time is too long lead to excessive sludge concentration? Try to keep the sludge concentration of 97% or so, too much, then the agent is not easy and completely mixed with the sludge. For more information, please pay attention to our belt filter press knowledge blog.
Cause four: there may be equipment failure filter filter with a problem, the plastic drum failed. Last time I plant equipment on this issue, leading to the old side of the shift
1, may filter cloth size selection is wrong, too fine run mud, too large mud.
2, rinse water pressure enough, but the water is not enough (rinse hole blocked).